We have a dozen or more CR1000 loggers, a few dozen CR10x’s and even still some CR21X’s that are still chugging along. Well done!Anywaythe CR1000’s are connected via an IP network …
仪器使用
Yes, this is possible. Keep in mind, however, that a common ground between related devices is essential for obtaining a good measurement. …
I'm pretty new to the CR1000 so this may be a no-brainer question but here it is.Is there any way to have the data logger disregard invalid data? As a test, I've deliberately disco …
The maximum voltage sourced through the SW12V is 16 Vdc. …
The maximum current is dependent on temperature:0.9 A @ 20° C0.65 A @ 50° C0.36 A @ 85° CThese limits are set by the polyfuse incorporated in the device. …
How can i set datatable to be ring mode?新对话如下:Datatables are ring mode by default. To make them fill and stop you need to include the Fillstop instruction in the program. …
Hi, i am work trying to connect one WXT520 weather transmitter with the Datalogger CR200, but i can't.I am using the command SDI12Recorder but I don't know what put in the paramete …
Relatively new to CS and currently using a CR10X and PC200w to collect data and drive a number of output actions:turn onoff pumps, lights, etc. Curious to know if anyone can direct …
No. The RF401 only transmits at the 100 mW level. If additional power is needed, a directional antenna or a high-gain omnidirectional antenna can be used to increase the effective …