To all,
I need some general tips to setup a Cr1000 to handle the following communication:
1. RS232 port connected to wavecom modem to send and receive short messages and for remote support dial up.
2. NL115 connected to a few Pc's using Loggernet and the web Interface the logger creates
3. CS I/O connected to a master PC using Loggernet
The logger drop the comms to a Pc as soon as more than one is connected via Loggernet. Any help will be appreciated.
Thanks
James
Make sure that all the copies of Loggernet are assigned different Pakbus addresses for the PAkbus port they are using to connect to the logger, otherwise the Logger "gets confused" as to which Loggernet server is where.
To change the Pakbus address of the Pakbus port on the Loggernet server, open the Setup screen and select the function under the Options drop down menu. 4094 is the default. Select addresses >3999 and <4094.
This must be done for each PC which is going to connect at the same time.