No. The HC2A-S3 is fully compatible with the analog CRBasic instructions used for the retired HC2S3-L sensor. …
I recently purchased a 05103-66 and sutron 6661-1256 interface assembly.This is not what I thought it was but I would like to try to get this going. It is used military surplus but …
No. The HC2A-S3 is fully compatible with the HC2S3CBL1-L cable (active set) and uses the same wiring colors. …
Hi Folks, I use Loggernet to remotely connect to my loggers via an NL100 connected to a freewave radio network.Yesterday the the connection only worked at 7am and then was down for …
The ClimaVUE™50 is a microclimate sensor, so you should position it to be representative of the climate relevant to the research questions you are asking. FAO56 gives specifi …
Does simulation software exist to run, test, debug code without loading into the datalogger?新对话如下:The only thing to validate the code is the pre-compiler in CRBasic Editor, but tha …
I would like to use the Status table fields in my program.OKFlag If Status(watchdogerrors)=0How can I access the status table in the program?新对话如下:Hi,Look at the data table access …
We do not have a heated version of the ClimaVUE™50 at this time. The model to correct the air temperature is based on the energy balance and should be good in all situations …
The ClimaVUE™50 does need to be powered continuously to make the routine wind measurements (every 10 seconds) that are combined to give the wind speed and direction. If you o …
Hello,I like used the instruction ”AcceptDataRecords” to set up a datalogger so that it will accept and store records from a remote datalogger. When I was to compiler the program u …