多参数记录仪 (3-5 参数)RBRconcerto³是加拿大RBR公司基于多年的经验设计并制造生产的多通道水质记录仪,可支持3-5个传感器,其性能可靠,易于使用。广泛应用于海洋锚系和剖面测量。既可以自容式使用,又可以选择实时数据输出版本。用户可以对RBRconcerto³进行灵活的测量设置,标配采样率为2Hz(用户大可选32Hz)。大容量数据存储功能,和U …
Ensure that the versions of RTMC products match (same version for Run-Time and Developer). …
We are logging data in CR1000 loggers.Does anyone know if there is a feature whereby the internal clock will automatically switch to the time changes.To eliminate confusion, we ref …
Yes. RTMC Pro includes options to export entire screens or specific objects. These images can then be incorporated into a separate web page. …
Hello!Output of binary data (currently 10 Byte) using the SerialOutBlock command via the ComRS232 of a CR1000 works correct. With a baudrate of 9600 (8,o,2) the byte spacing is abo …
LoggerNet Admin can be run as a service by installing the included LoggerNet service manager. Projects published as web pages to the CSI Web Server will also run as a service. …
I recently upgraded to v.4 from v.3.4 and I can't find the SMS module.I'm using both SM4M and CSM1 to expandbackup old dataloggers (21x and CR10) memory.Could it be that SMS is not …
This can be done by comparing the last time stamp of the value with the current system time within an IIF() function. …
Hi,Our 7500 has recently started to log NAN's as pressure and CO2H2O has increased. I understand I need to zero and span, however I am wondering if that is going to solve the press …
Consider using IIF(). Here is an example of using the last value instead of the -6999 in a min run over a day with temp avg:Alias(X, "Server:CR1000.HOUR.Temp_F_Avg"); StartRelative …